Products

TTYCYSLA CS Shipboard Instrumentation Cable

Standard: JIS C3410-2010
Material: Cu/PVC/PVC/Al-foil/PVC/Steel Wire/PVC
Certificate: ABS, LR, BV, GL, RINA, DNV, NK, KR, CCS
Application:  for instrumentation, communication, control and alarm system in both explosion risk and safe areas, general purposes.

TTYCY-SLA Individual Shielded Shipboard Instrumentation Cable 150/250V

TTYCY-SLA IS Shipboard Instrumentation Cable 150/250V  Application

The TTYCY-SLA shipboard cable is used for instrument circuit up to 250V, instrument safe systems, also for fixed installation for the instrument, communication, control and alarm system in both explosion risk and safe areas, general purposes.

Cable Type:

TTYC-SLA, FA-TTYC-SLA, TTYCY-SLA, FA-TTYCY-SLA

STANDARDS

Design guide JIS C 3410(2010),IEC 60092-350(2008-02),

IEC 60092-351(2004-04),
IEC 60092-353(2001-04),
IEC 60092-359(1999-08),
IEC 60092-376(2003-05)
IEC 60332-1
IEC 60332-3 Cat.A(for FA-type)

Individual Screened Shipboard Instrumentation Cable 150/250V Construction

Conductor TT
TTP
Tinned annealed stranded copper (TTY-type) Tinned annealed stranded
copper (TTPY-type), class 2 according to IEC 60228
Insulation 60°C PVC(TTY-type)/ 85°C EPR(TTPY-type) as per JIS C 3410
Twisting Two Insulated cores shall be twisted together to form a pair
Cabling Twisted pairs shall be cabled.
Flame retardant & non-hygroscopic fillers may be used
Shield -SLA Individual Shield with Aluminium foil-mylar tape
Bedding Y PVC as per JIS C 3410
Armor C Galvanized steel wire braid
Sheath Y PVC as per JIS C 3410
Core identification Printed pair number and Alphabet letter on the white insulation.
ex) 4P : (1A, 1B), (2A, 2B), (3A, 3B), (4A, 4B)
– 1T, 1Q cable shall be identified by the black number on the white
insulation
Outer sheath color Black

FA-TTYCY Shipboard Telephone and Instrumentation Cable 150/250V Specification

150/250V (FA-) TTYC-SLA,TTPYC-SLA

No. of pairs No. of cores Conductor Nominal overall diam. Tolerance overall diam. Cable weight(Approx.)
Size Construction O.D
No. No. SQ No./mm mm mm ± mm kg/km
4 8 0.75 7/0.37 1.11 17.3 0.7 380
7 14 0.75 7/0.37 1.11 20.8 0.8 545
10 20 0.75 7/0.37 1.11 26.5 1.1 805
14 28 0.75 7/0.37 1.11 28.9 1.2 980
19 38 0.75 7/0.37 1.11 32.7 1.3 1320
24 48 0.75 7/0.37 1.11 38.4 1.5 1710
30 60 0.75 7/0.37 1.11 40.9 1.6 1970
37 74 0.75 7/0.37 1.11 44.1 1.7 2300
48 96 0.75 7/0.37 1.11 50.9 1.9 2960

150/250V (FA-) TTYCY-SLA,TTPYCY-SLA

No. of pairs No. of cores Conductor Nominaloverall diam. Tolerance ofoverall diam. Cable weight(Approx.)
Size Construction O.D
No. No. SQ No./mm mm mm ± mm kg/km
4 8 0.75 7/0.37 1.11 19.5 0.8 465
7 14 0.75 7/0.37 1.11 23.2 0.9 660
10 20 0.75 7/0.37 1.11 29.3 1.2 970
14 28 0.75 7/0.37 1.11 31.7 1.3 1160
19 38 0.75 7/0.37 1.11 35.7 1.4 1540
24 48 0.75 7/0.37 1.11 42 1.6 2020
30 60 0.75 7/0.37 1.11 44.5 1.7 2300
37 74 0.75 7/0.37 1.11 47.9 1.8 2670
48 96 0.75 7/0.37 1.11 55.1 1.9 3440

DISCLAIMER: Please note that the above specifications are “general specifications” that pertain to the majority of our production. Specifications and technical details should only be used for general, informational purposes only. For the actual specification, please check with us when order placed.

Reviews

There are no reviews yet.

Be the first to review “TTYCYSLA CS Shipboard Instrumentation Cable”

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.