Products

Type 209 Mining Trailing Cable 1.1 to 11KV

Standard:AS/NZS 1802:2003
Application: Type 209 series cable is mainly used as a flexible feeder to machinery, more suitable as a trailing cable rather than for reeling. Smaller cables are used for drills and hand-held tools and equipment.

Type 209 Mining Trailing Cable 1.1 to 11KV

Type 209 Mining Trailing Cable 1.1 to 11KV Application

Type 209 series cable is mainly used as a flexible feeder to machinery, more suitable as a trailing cable rather than for reeling. Smaller cables are used for drills and hand-held tools and equipment. This cable can be used as a trailing cable to be a flexible feeder to machinery. Smaller conductor sizes may also be used for power feeder cable to equipment such as drills, pumps, crusher, etc. Suitable for use in underground coal mining applications.

Type 209 Mining Trailing Cable 1.1 to 11KV Standard

AS/NZS 1125,
AS/NZS 3808,
AS/NZS 1802,
AS/NZS 5000.1

Type 209 Mining Trailing Cable 1.1 to 11KV Construction

Type 209 Mining Trailing Cable 1.1 to 11KV Construction

Type 209 Mining Trailing Cable 1.1 to 11KV Construction

3×Conductors  Flexible stranded tinned annealed copper conductor.
Conductor Screen  1.1/1.1kV – polyester barrier tape,
3.3/3.3kV and above – polyester barrier tape and
extruded semiconductive tape.
Insulation  EPR.
Insulation Screen  Semiconductive tape.
Composite Screen (earth conductor) Tinned annealed copper braiding interwove with polyester yarn.
Cradle Separator  Semiconductive PCP.
1×Central Extensible Pilot EPR covered flexible stranded tinned copper conductor.
Sheath  Heavy duty PCP sheath.

Type 209 Mining Trailing Cable 1.1 to 11KV Technical Data

Voltage Rating   1.1, 3.3, 6.6, 11kV
Operating Conductor Temperature   -25 to 90°C
Emergency Conductor Temperature   130°C
Short Circuit Conductor Temperature   Max. 250°C for 5 sec
Max. Working Tension   0.02kN/mm² (total)

Type 209 Mining Trailing Cable 1.1 to 11KV Specification

Type 209.1

Nominal
Conductor Area
Insulation
Thickness
Core screen
Area of Screen
Pilot Conductor
Thickness of Covering
Thickness of
Sheath
Nominal
Overall
Diameter
Nominal
Weight
mm2 mm mm2 mm mm mm kg/100m
6 1.5 7.2 0.8 3.8 30 129
10 1.5 8.6 0.8 3.8 32.6 157
16 1.6 9.6 0.8 4 35.8 197
25 1.6 11.3 0.8 4.3 39.7 255
35 1.6 12.4 0.8 4.6 43.1 312
50 1.7 14.1 0.8 5 47.7 386
70 1.8 16.5 0.8 5.4 54 503
95 2 18.2 0.8 6 58.6 605
120 2.1 20.3 0.8 6.4 64.4 741
150 2.3 22.3 0.8 6.9 70.2 896
185 2.5 30.2 0.8 7.4 77.4 1092
240 2.8 33.6 0.8 8.2 86 1365
300 3 50.1 0.8 8.8 95.1 1715

Type 209.3

Nominal
Conductor Area
Insulation
Thickness
 Core screen
Area of
Screen
 Pilot Conductor
Thickness of
Covering
Thickness of
Sheath
Nominal
Overall
Diameter
Nominal Weight
mm2 mm mm2 mm mm mm kg/100m
16 3 13.1 0.8 5.3 46.2 301
25 3 14.8 0.8 5.6 50.1 369
35 3 15.8 0.8 5.9 53.5 431
50 3 17.2 0.8 6.3 57.6 507
70 3 18.6 0.8 6.6 62.5 624
95 3 20.3 0.8 7.1 66.2 719
120 3 27.2 0.8 7.4 72 876
150 3 39.6 0.8 7.8 78 1072
185 3 42.2 0.8 8.2 83.4 1236
240 3 46.6 0.8 8.8 90.3 1500
300 3 63.2 0.8 9.4 98.4 1840

Type 209.6

Nominal
Conductor Area
Insulation
Thickness
 Core screen
Area of
Screen
 Pilot Conductor
Thickness of
Covering
Thickness of
Sheath
Nominal
Overall
Diameter
Nominal Weight
mm2 mm mm2 mm mm mm kg/100m
16 5 17.2 0.8 6.4 57.3 435
25 5 18.6 0.8 6.7 61.2 512
35 5 18.6 0.8 7 64.6 582
50 5 21.3 0.8 7.3 68.5 668
70 5 23.4 0.8 7.7 73.7 799
95 5 29.2 0.8 8.1 77.8 935
120 5 31.7 0.8 8.5 83.1 1090
150 5 45.7 0.8 8.9 89.1 1310
185 5 48.4 0.8 9.3 94.5 1480
240 5 52.8 0.8 9.9 101.4 1750
300 5 71.5 0.8 10.4 109.3 2120

Type 209.11

Nominal
Conductor Area
Insulation
Thickness
 Core screen
Area of
Screen
 Pilot Conductor
Thickness of
Covering
Thickness of
Sheath
Nominal
Overall
Diameter
Nominal Weight
mm2 mm mm2 mm mm mm kg/100m
25 7.6 23.7 0.8 8.1 75.6 750
35 7.6 30.2 0.8 8.4 79.7 858
50 7.6 31.7 0.8 8.7 83.6 960
70 7.6 34.1 0.8 9.1 88.8 1093
95 7.6 47.5 0.8 9.6 93.7 1267
120 7.6 51 0.8 9.9 98.8 1436
150 7.6 53.7 0.8 10.3 103.5 1614
185 7.6 57.2 0.8 10.7 108.8 1830

Please note that the above specifications are “general specifications” that pertain to the majority of our production. These specifications should only be used for general, informational purposes. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All specifications are subject to change without prior notice. All pictures shown are for illustration purposes only. Actual product may vary.

Reviews

There are no reviews yet.

Be the first to review “Type 209 Mining Trailing Cable 1.1 to 11KV”

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.